Not only Earth
and Insulation Resistance, a wide range of additional measurements are
available. |
|
|

Earth Resistance -
two clamps
(Rodless
method for urban environment) |

Insulation
Resistance
EN
61557-2
(Extremely high meas. range) |

Varistor
Overvoltage
Protection Devices |
|

Particular Earth
Resistance - one clamp
(No opening of rusty junctions) |
 |

Current (True RMS)
(0.1mA up to 200A) |
|

Earth Resistance
EN61557-5 |

Continuity of
Protection
Conductors
EN61557-4
(One-hand operation, remote commands) |
|

Earth Resistance
EN61557-5
(Huge and complex objects) |

Specific Earth
Resistance
EN61557-5 |

Continuity
(Continuous
function for quick tests)
|
 |
|
Measurement per each set |
|
|
|
●●●
Earth-Insulation
Set 20 m |
|
Specific Earth Resistance
●●
|
|
●●●
Earth-insulation Set
50 m |
|
Display range
|
0
÷1999 kΩm
(kΩft)
|
|
●●●
Insulation
Set |
|
Calculation
|
p =2תּaRE
|
| |
|
Distance between test rods
|
1÷30
m (1÷90
ft) |
|
TECHNICAL SPECIFICATION |
|
Other characteristics see
under four-lead method |
|
Insulation Resistance●●●
|
|
Voltage a. c/d●●●
|
|
Display range Riso (Un>25OV) |
0-000M÷29.9GΩ |
|
Display range |
0÷600 V
|
|
Display range Riso (Un<25OV) |
0-000M÷199.9M |
|
Accuracy |
±(2 % + 2 D)
|
|
Resolution |
0.001; 0.01; 0.1; 1; 10; 100MΩ |
|
Nominal frequency range
|
45÷65
Hz, d. c |
|
Accuracy |
±(2 % + 2 D)... (0 ÷199.9 MΩ) |
|
Current (True RMS)
A1018,1019
|
|
Nominal test voltage |
50÷1000 V in steps of 10 V |
|
Measurement principle
|
current clamp 1 A / 1 mA |
|
Generator current capability |
> 1 mA at Unom.0 |
|
Display range |
0÷200A |
|
Display range (test voltage) |
0÷1200 V |
|
Resolution |
0. 1; 1
mA; 0. 0 1; 0. 1; 1
A |
|
Continuity of Protection Conductors
(single measurement)
●●●
|
|
Basic accuracy |
±(5 % +5 D) (0.5 mA÷ 200 A)
|
|
Display range |
0.00÷19.99 20.0÷199.9 200÷1999 |
|
Nominal frequency |
50/60 Hz |
|
Accuracy |
±(2 %+2D) ±(3 %)Ω |
|
Varistor Over voltage Prot. Devices - Breakdown
●●● |
|
Test current |
>200mA |
|
Measurement principle
|
dc, voltage
ramp (500 V/s |
|
Compensation of test leads (up to 5 Q) |
yes |
|
Display range |
50÷1000V |
|
Automatic polarity exchange |
yes |
|
Accuracy |
±(5 % + 10 V) |
|
Continuity (continuous
measurement)●●●
|
|
Threshold current
|
1 mA |
|
Display range |
0.0÷199.9Ω
200÷1999Ω |
|
GENERAL CHARACTERISTICS |
|
Accuracy |
+(3 % + 3 D) |
|
Power supply |
6 V(4 x 1.5 V IEC LR14) |
|
Short-circuit test current |
<7 mA |
|
Visual and acoustic warnings
|
yes
|
|
Earth Resistance (four-lead method)●● |
|
Display |
custom design LCD
(with backlight) |
|
Display range |
0 ÷19.99 kΩ |
|
Memories |
approx. 1000 measurements |
|
Resolution |
0.01; 0.1; 1; 10Ω |
|
Computer connection
|
RS 232 |
|
Basic accuracy |
±(2 % + 3 D)... (0÷2 KΩ) |
|
Dimensions (w x h x d)
|
265 x 110 x 185 mm |
|
Test voltage |
<40 V/ 125 Hz/sine, wave |
|
Weight (without acces, with
batteries)
|
1.7kg |
|
Short-circuit test current |
<20 mA |
|
Protection classification
|
double insulation |
|
High noise rejection |
yes |
|
Overvoltage category
|
CA T 111/300 V
or CA T 11/600 V |
|
Aut. potential and current probe res, test |
yes |
|
Pollution degree |
2 |
|
Earth Resistance (four-lead method+clamp)+●1●18
|
|
Degree of protection
|
IP 54 |
|
Display range |
0÷1.99kΩ |
|
Working
temperature range |
0÷40 oC |
|
Other characteristics see under four-lead method |
|
Max humidty |
85 % RH (0÷40°C) |
|
Earth
Resistance (two test clamps) A1018+A1019
|
|
Auto power OFF |
Yes |
|
Display range
|
0÷19.99Ω 20.0÷100.0Ω |
|
|
|
|
Basic accuracy
|
±(10% + 2D) ±(20%)
|
|
|
|
|
|
|
|
|
|
ORDERING INFORMATION |
EARTH INSULATION TESTER |
|
Earth-Insulation Set 0 20 m ● |
Earth Insulation Set 50m
●
|
Insulation Set ● |
|
Order No. |
MI2088-20 |
MI2088-50 |
MI 2088 |
|
Scope of supply |
|
|
|
|
Universal test cable 2 x 1. 5 m |
yes |
yes |
yes |
|
Earth test set - 20 m |
yes |
|
|
|
Earth test set - 50 m
|
|
yes |
|
|
Alligator clip |
yes |
yes |
yes |
|
Test tip (red) |
yes |
yes |
yes |
|
Test tip (black) |
yes |
yes |
yes |
|
RS232 cable |
yes |
yes |
yes |
|
PC SW Earth Link (for Windows
95/98/2000/NT/XP) |
yes |
yes |
yes |
|
Soft carrying bag |
yes |
yes |
yes |
|
Instruction manual |
yes |
yes |
yes |
|
Handbook 'Measurements on electric
installations in theory and practice" |
yes |
yes |
yes |
|
Declaration of conformity |
yes |
yes |
yes |
|
Production verification data |
yes |
yes |
yes |
|
Declaration of warranty |
yes |
yes |
yes |
| |
|
|
|
|
|
|
|
|
Optional
accessories |
|
|
|
|
Tip commanderOrder No. A 1002 |
yes |
yes |
yes |
|
Earth test set - 20 m Order No. 82001 |
|
|
|
|
General cable 4 x 1 m |
|
|
|
|
H test lead 20m |
|
|
|
|
S test lead 20m |
|
yes |
yes |
|
ES test lead 4.5 m |
|
|
|
|
E test lead 4.5m |
|
|
|
|
Earth test rod 4pcs |
|
|
|
|
Small soft carrying bag |
|
|
|
|
Earth test set - 50 mOrder No. S 2002 |
|
|
|
|
General cable 4 x 1 m |
|
|
|
|
H test lead 50 m wound-up on spool support |
|
|
|
|
S test lead 50 m wound-up on spool support |
|
|
|
|
ES test lead 4.5 m |
yes |
|
yes |
|
E test lead 4.5 m |
|
|
|
|
Earth test rod 4pcs |
|
|
|
|
Soft carrying bag - small |
|
|
|
|
Low-range clamp 0.5 mA up to 200
A Order No. A 1018 |
yes |
yes |
yes |
|
Standard-range clamp 10 mA up to 200 AOrder No. A 1019 |
yes |
yes |
yes |
|
General cable 4 x 1 m Order No. A 1021 |
|
|
yes |