Instaltest 61557
See also
Instaltest-Eurotest
Accessories |
|
|
 |
|
2
Voltage Logging
( voltage
recording through a
certain
period of
time,recording
of slow transient phenomena)
|
|
8
Line Resistance and
lpsc
EN 61557-3
(115/230V mains system) |
|
7
Fault Loop Resistance and lpsc
EN 61557-3
(115/230V mains system) |
|
10
Fault Loop
Resistance
EN 61557-6
(no tripping out RCD) |
|
 |
Wide range of subfunctions and
tests, ensure simple maintaining and quick troubleshooting
|
 |
Plug-and-Tip commanders offer
one-hand operation (measuring and storing results)
|
 |
High immunity against input
transients, thanks to unique hardware input protection
|
 |
PC SW
Instal Link assures simple and clear handling of test results (Instaltest
only)
|
 |
Exhaustive graphic Help menus, provide connection diagrams for each
measurement (Eurotest only) Unique PC SW Euro Link -Pro supports entire test
procedure (Eurotest only)
|
 |
Extended Earth Resistance measurement (Eurotest only)
|
 |
Intemet upgradable (Eurotest only)
|
Five patented solutions! 
|
|
|
Other functions
(See the Eurotest) |
| |
|
|
|
|
|
|
|
We are so sure that the EUROTEST
is a GREAT BUY that if you buy the
Eurotest and are not happy with it we will swap it for an AVO CM500 at no
extra cost *some conditions apply |
|
|
|
Eurotest 61557 |
|
Line Impedance and lpsc
EN 61557-3
(115 / 230
/ 400 V mains system)
|
|
Fault Loop
Impedance and Ipsc
EN 61557-3
Contact Voltage
at Ipsc -SEV 3569
Efficiency of additional equalizing) |
|
N-PE Loop / Earth
Resistance and lpsc
(Internal test voltage, no trip out RCD)
|
|
Sensor Input
(Measurement of illumination and other) |
|

|
|
Complete RCD analysis EN 61557-6
(Automatic
test, without or with probe, Fault Loop
Resistance without tripping RCD)
|
|
Fuse/Fault/Cable Locator
(Enables troubleshooting and detecting
of
individual installation parts)
Phase rotation EN 61557-7
|
|
True RMS Current
(No need to
care for Current shape)
Peak Current
(To measure
e.g. start-up currents)
|
|
Harmonics up to 21 st Voltage and
Current (Electric power quality) |
|
|
|
|
|
Earth Resistance EN 61557-5
4-terminal 2-test rod method
One-clamp method
(No disconnection of rusty bonds)
Two-clamp method
(Rodless, for urban environment)
Specific Earth Resistance
EN61557-5
|
|
Continuity of Protection
Conductors EN 61557-4
(up to 2
kohm)
Continuity (continuous function)
Low
test current for diodes, and other quick tests) |
|
Insulation Resistance EN 61557-2
(Test
voltages 50, 100, 250, 500 and 1000 V)
Varistor Overvoltage Devices - U
breakdown
(Voltage
ramp 500 V/s threshold current 1 mA) |
|
Power W, VA, Var, cos Ø, Energy
(True RMS current,
True RMS voltage) |
|
|
 |
TECHNICAL CHARACTERISTICS Eurotest 61557/Instaltest 61557
|
|
Insulation Resistance
|
|
Display range |
1-1000MΩ
(Un>25OV) 0-200MΩ
(Un>25OV) |
|
Resolution |
0.001 0.01
0.1 1 MΩ |
|
Accuracy |
±(2 % + 2 D) ...
(0 - 200 MΩ) |
|
Test voltage |
50
100 250 500 1000 V |
|
Generator current capability |
>1
mA |
|
Continuity of Protection Conductors (single
measurement) |
| Display range 0 |
0.00 - 19.99
20.0-2999.9 200-2000Ω |
| Accuracy |
±(2 % + 2 D)....(0-20Ω) |
| Open-terminal
test voltage |
4 - 7 Vd.c. |
| Test current |
>200 mA |
| Compensation of
test leads |
Yes |
| Automatic
polarity exchange |
Yes |
|
Continuity
(continuous measurement) |
| Display range |
0.0-199.9Ω
200-2000Ω |
 |
Accuracy |
±(3%
+ 3 D) |
| Short-circuit
test current |
>7mA |
| Open-terminal
voltage |
4 - 7 Vd.c. |
|
Earth Resistance (four-lead
method) |
|
Display range |
0 -
20 kΩ |
|
Resolution |
0,01, 0.1, 1; l0Ω |
|
Basic accuracy |
±2
% + 3 D)... (0 - 2 kΩ) |
|
Test voltage |
40 V(d.c.)
/ 125 Hz / sine wave |
 |
Short-circuit test current |
.20mA |
|
Aut potential and current probe res test |
yes |
|
Earth Resistance (four-lead
method + clamp) |
|
See the characteristics under four-lead method |
|
|
Earth Resistance (two test
clamps) |
|
Display range |
0-
1999Ω 20.0 - 100.0
Ω |
|
Basic accuracy |
±10%+2D)
±(20 %) |
|
Specific Earth Resistance |
|
Display range |
0-2000kΩm |
|
Calculation |
p =תaRe |
|
Distance between test rods |
1 - 30 m |
|
RCD Protection Devices - general data |
| -------
Eurotest 61557 |
----
Instaltest 61557 |
Nom. test
current- - |
10, 30, 100, 300, 500,
100OmA(0-180oC) |
| RCD type |
AC, standard or selective |
|
RCD - contact Voltage |
| Display range |
0.00-9.99 10.0-100V |
|
Resolution |
0.01
0.1V |
|
Basic accuracy |
(-0/+10)% ± 0.2V
(-0/+10)% |
|
Test current |
>0.5l∆N |
|
|
|
|
RCD - Earth/loop Resistance |
|
Peak Current |
|
Measurement principle |
with or with out
probe |
|
Display range |
5-280A |
|
Display Range |
0- 10kΩ |
|
Basic accuracy |
± (5%) |
|
RCD - Trip out Time |
|
Varistor Overvoltage Prot. Breakdown Voltage |
|
Display range (general type) |
0 - 300 ms (0.5 I∆N, I∆N)
0-150ms(2I∆N) 0-40ms(5
I∆N) |
|
Measurement principle |
d.c. voltage ramp (500 V/s) |
|
Display range (selective type) |
0 - 500 ms (0.5
I∆N, I∆N)
0-200ms(2 I∆N)
0-150ms (5 I∆N) |
|
Display range |
50 - 1000 V |
|
Accuracy |
±3 ms |
|
Accuracy |
± (5% + 10V) |
|
RCD - Tripping Current |
|
Fault, Fuse, Conductor Locator |
|
Display range I∆ |
(0.2 - 1.1) I∆N |
|
Principle |
Loading of mains voltage or applying a test
signal |
|
Display range t∆/I∆ |
0-300ms |
|
Loading |
Is < lA pulsed fs=3600Hz Un=30 - 264V/ 45 -
65Hz |
|
Display range Uci (Uc/U∆ |
0- 100 V |
|
Imposing |
Us <7 V pulsed fs = 3600 Hz Isc <50 mA pulsed |
|
Fault Loop Impedance
/Resistance and Ipsc |
|
Power (one-phase) |
|
Display range Z
R, X |
0.00 - 19.99 20.0 - 199.9 200 -
2000Ω |
|
Display range |
0 - 88k W/VA/Var |
|
Accuracy Z, R, X... Eurolest |
± (2% + 3 D) |
|
Resolution |
0. 1 1 0.01 k 0. 1 k W/VA/Var |
|
Accuracy R ...Instaltest |
±(5% + 5 D) |
|
Accuracy |
±(7 % + 1 D) |
|
Display range Ipsc |
0.06 A - 24.4 kA |
|
Nominal voltage. frequency |
10 - 440 V, 50160 Hz |
|
Nominal voltage |
100 264 V 45-65Hz |
|
Display range cosø |
0-1 |
|
Contact Voltage at
Prospective Short-circuit Current |
|
Energy |
|
Display range |
0.00 - 9.99 10.0 - 99.9
100 - 264 V |
|
Calculation |
W = Σ P x ∆t |
|
Accuracy |
(3% + 0.02Ω
x Ipsc) |
|
Display range |
0-2000 kWh |
|
Line Impedance/Resistance
and lpsc |
|
Accuracy |
± (7% + 1 D) |
|
Display range Z,
R, X |
0.00 - 19.99 20.0 - 199.9 200 -
2000Ω |
|
Harmonic Analysis (Voltage
and Current) |
|
Accuracy Z, R, X ...Eurotest |
± (2% + 3 D) |
|
Component range |
odd values up to 21-st |
|
Accuracy R.... Instaltest |
±(5% + 5 D) |
|
Display-range (each
component) |
0.0 -100.0% |
|
Display range Ipsc |
0.06 A - 42,4 kA |
|
Display range (THD) |
0.0 -1000% |
|
Nominal voltage |
100 - 440 V 45 - 65 Hz |
|
Accuracy |
(5% + 5 D) |
|
N-PE Loop /Earth Resistance
and lpsc |
|
Voltage measurement (True RMS) |
0-440 V |
|
Test method |
internal generator (Earth resistance) |
|
Current measurement (True RMS) |
0-200A |
|
Display range R I-pe |
0.00-19.99 20.0 - 199.9 200 -
2000Ω |
|
Nominal frequency |
50/60 Hz |
|
Accuracy R I-pe |
±(2 % + 3 D) |
|
|
|
|
Display range Ipsc |
0.06 A - 24.4 kA |
|
GENERAL CHARACTERISTICS |
|
Phase Rotation |
|
Power supply |
6 V (4 x 1.5 V IEC LR14) |
|
Display of result |
1.2.3 or 2.1.3 |
|
Automatic evaluation of test results |
yes
|
|
Voltage |
Frequency |
|
Visual and acoustic warnings |
yes |
|
Display range |
0-440 V 45.0 - 65.0 Hz |
|
Display |
graphic LCD
(with backlight) |
|
Accuracy |
+-(2% + 2D) ± 0.2 Hz |
|
Memories |
2000 meas.(Eurotest) 1000 meas.(lnstaltest) |
|
Nominal frequency range |
45 - 65 Hz |
|
Computer connection |
RS 232 |
|
Current (True RMS) |
|
Dimensions (w x h x d) |
265 x 110 x 185 mm |
|
Measurement principle |
current clamp |
|
Mass (without access with bat.) |
2.1 kg (Eurotest) 1.8 kg (Instaltest) |
|
Display range |
200 A |
|
Protection classification |
double insulation |
|
Resolution |
0.1 1 mA 0.01
0.1 1A |
|
Overvoltage category |
111/300 V or 11/600 V |
|
Basic accuracy |
± (5%)... (0.1 - 100 A) |
|
Pollution Degree |
2 |
|
Nominal frequency |
50/60 Hz |
|
Degree of protection |
IP 44 |
| |
|
|
Working temperature range |
0 - 40ºC |
| |
|
|
Max. humidity |
85 % RH (0 - 40ºC) |
| |
|
|
Auto power OFF |
yes |
 |
| |
|
|
|
|
 |
| |
|
|
|
| FUNCTION |
Eurotest |
Instaltest
|
REQUIRED ACCESSORIES |
|
Insulation Resistance |
√ |
√ |
Tip Commander
or Universal Cable |
|
Continuity of Protection Conductors |
√ |
√ |
Tip Commander or
Universal Cable |
|
Continuity |
√ |
√ |
Tip Commander or
Universal Cable |
|
Earth Resistance (Four-terminal method) |
√ |
|
Earth Test Set -
20 m or Earth Test Set - 50 m |
|
Earth Resistance (Four-terminal method + clamp) |
√ |
|
Earth Test Set - 20 m or Earth
Test Set - 50 m
Low-range Current Clamp |
|
Earth Resistance (Two-clamp method) |
√ |
|
Clamp Test Set |
|
Specific Earth Resistance |
√ |
|
Earth Test Set -
20 m or Earth Test Set - 50 m |
|
Fault Loop Impedance, lpsc |
√ |
|
Universal Cable |
|
Line Impedance, lpsc |
√ |
|
Universal Cable |
|
Contact Voltage at lpsc (SEV 3569) |
√ |
|
Universal Cable
Probe Test Lead |
|
Fault Loop Resistance, Ipsc |
√ |
√ |
Tip
Commander or Universal Cable |
|
Line Resistance, Ipsc |
√ |
√ |
Tip Commander or
Universal Cable |
|
RCD - Contact Voltage at l∆n
RCD - Trip out time
RCD - Tripping
current
RCD - Loop
Resistance |
√ |
√ |
Universal Cable |
|
RCD - Earth Resistance |
√ |
|
Universal Cable
Probe Test Lead and Earth Rod |
|
Phase Rotation |
√ |
√ |
Universal Cable
or Three-Phase Cable |
|
Fuse, Fault, Conductor Tracing |
√ |
√ |
Universal Cable
Locator |
|
Power, cosø, Energy
Harmonics |
√ |
|
Universal Cable
Standard-range current Clamp |
|
True RMS Current |
√ |
|
Standard range
curr. Clamp or Low-range curr. Clamp |
|
Varistor Overvoltage Device-
Breakdown Voltage |
√ |
√ |
Universal Cable |
|
Voltage Logging |
√ |
√ |
Universal Cable |
|
|
|
|
|
Ordering
Information |
Eurotest 61557
Euro Set |
Eurotest 61557 Standard Set |
Instaltest 61557 Standard Set |
|
Order No. |
MI 2086 EU |
MI 2086ST |
MI2087 ST |
|
SCOPE OF SUPPLY |
|
|
|
|
Plug Commander |
√ |
√ |
√ |
|
Universal test cable 3 x 1. 5 |
√ |
√ |
√ |
|
Low-range Clamp 1 A/1 mA |
√ |
|
|
|
Probe test lead 4 m |
√ |
|
|
|
Alligator clip |
√ |
√ |
√ |
|
Test tip (blue) |
√ |
√ |
√ |
|
Test tip (black) |
√ |
√ |
√ |
|
RS232 cable |
√ |
√ |
√ |
|
PC SW Euro Link - Pro (for
Windows 95/981/2000/NT/XP) |
√ |
|
|
|
PC
SW Euro Link - St (for Windows 95/98/2000I/NT/XP) |
|
√ |
|
|
PC SW Instal Link - (for Windows
95/98/2000I/NT/XP) |
|
|
√ |
|
Neck and back belts |
√ |
√ |
√ |
|
Soft carrying bag |
√ |
√ |
√ |
|
Instruction manual |
√ |
√ |
√ |
|
Handbook, Measurements on
electric installations in theory and practice" |
√ |
√ |
√ |
|
Declaration of conformity |
√ |
√ |
√ |
|
Production verification data |
√ |
√ |
√ |
|
Declaration of warranty |
√ |
√ |
√ |
| |
|
|
|
|
Optional accessories |
|
|
|
|
|
Tip Commander
|
Order No.A 1002 |
√ |
√ |
√ |
|
Fuse / fault / cable Locator
|
Order No. A 1005 |
√ |
√ |
√ |
|
LUX meter probe |
Order No. A 1102 |
√ |
√ |
|
|
Probe test lead 4 m
|
Order No. A 1012 |
|
√ |
|
Earth test set - 20m
General cable 4 x 1 m
H test lead 20 m
S test lead 20 m
ES test lead 4.5 m
E test lead 4,5 m
Earth test rod 4pcs
Small soft carrying bag |
Order No. S 2001 |
√ |
√ |
|
|
Earth test set - 50 m
General cable 4 x 1 m
H test lead 50 m wound up
on spool support
Test lead 50 m wound up on
spool support
ES test lead 4.5 m
E test lead 4.5 m
Earth test rod 4pcs
Soft carrying bag |
Order No. S 2002 |
√ |
√ |
|
|
Low-range Clamp 1 A/1 mA
|
Order No. A 1018 |
|
√ |
|
|
Standard-range Clamp 1A/1mA
|
Order No. A 1019 |
√ |
√ |
|
|
Three phase cable
|
Ref. No. A 1110 |
√ |
√ |
√ |
|
Three phase adapter
|
Ref. No. A 1111 |
√ |
√ |
√ |
|
General cable 4
x 1 m
|
Ref.No. A 1021 |
√ |
√ |
√ |
 |
See also
Instaltest-Eurotest Accessories
|